    Feb 7, 2009
    6,040
    96
    Houston, TX
    Rimfire suppressors get dirty. That is a well known fact of life that everyone that shoots 22 long rifle through a suppressor is familiar with.

    WARNING. Do not use peracetic acid to clean aluminum parts and aluminum baffles. It will eat them.

    This particular Dead Air Mask HD has been used for over a year on multiple host weapons. There are probably over 5000 rounds through it. Its been used for demos with my www.Texasguntrust.com clients, raccoon hunting, my kids almost exclusively shoot the Dead Air Mask HD, whenever a friend wants to shoot, he generally gets this suppressor.

    The build-up of lead and carbon is stunning if you have not seen it before.

    The fact that the suppressor came apart with a few shakes after this many rounds and this much build-up is a testament to the Dead Air Design team of Mike Pappas, Gary Hughes and Todd Magee.

    Once open, the baffles unsnapped and came apart into their individual pieces without any effort.

    A couple of the baffles had so much build-up, that the build-up looked like a damaged baffle. It took me a few seconds to realize that this wasn't a baffle strike that I was looking at, but the lead and carbon buildup that had molded itself into a mirror of the baffle ahead of it.

    After a cursory inspection of the build-up on the baffles, It was obvious that the only way to remove the lead build up was with the peracetic acid solution commonly known as the dip. I prepared a solution of 50% white vinegar and 50% hydrogen peroxide in a mason jar.

    30c93b4c57034de02471b5161698ce66.jpg

    The Dead Air Mask HD's front cap opened up easily. I was able to push the complete baffle stack out by gently shaking the suppressor and lerting it slide out.

    The fact that the entire baffle stack literally slid out after this many rounds is a testament to the design Genius of the Dead Air Mask HD engineering team of Mike Pappas, Gary Hughes and Todd Magee.

    9a9230318af3d7292cfb5f33c645ae30.jpg


    One interesting fact that I failed to notice until looking at these photographs is the lack of buildup on the outside of the baffle stack. These baffles sealed together very tightly and did not allow leading carbon to build up between the baffle stack and the tube of the silencer.

    4af8a449c43d4cfdc629ad157c6e24f8.jpg

    All the baffles are laid out for this photograph. If you look you can see the build-up of lead and carbon in almost all of the baffles.

    The outside of the baffle stack is relatively clean and free of buildup. These baffles seal together very tightly.

    474a5287e07b3cbf421bf3e34f4fcce3.jpg


    5ddea198a2c6b19a6a5cfe80fc7cadaa.jpg

    I wanted to see how hard the carbon and lead buildup was. A hammer and punch were the appropriate tools. I chipped some of the lead off using a the small hammer and a small punch. Definitely not the way to go about cleaning a suppressor that is fouled in this manner. This causes chips of Lead to go everywhere, it is very labor-intensive, has the potential to damage the baffle itself and does not remove enough of the lead condensate to make it worth the time and effort

    ed8ae0f72e09c61d48c4cde868db6930.jpg


    The blast chamber had a ring of material that had formed at the back of the blast baffle.

    0be08c9a295e60df2ccc91e3f1dd4350.jpg


    ca9608be73728a106da99b24124535b0.jpg


    28181253c5887408c6600f392644286d.jpg


    6e39458c6fe596e62f92c2730f0b1220.jpg


    10

    This is one of the first baffles that I saw as I disassembled the Mask HD. When I saw it, my first thought was that the baffle was destroyed due to a baffle strike. In fact, when I showed this picture the other people their first responses were how did you break it?

    It is fascinating to me that the lead and carbon would build up in such a way that the lead and carbon are molded into the shape of the cone of the baffle in front of it.

    5a38acb4ca0be70857485422eabbdca4.jpg


    If you look closely, this buildup follows the shape of the rear of the baffle cone ahead of it in the stack. The amazing thing is the suppressor never got noticeably louder as this build-up occurred.



    I soaked the baffles for 16 hours in the peracetic acid solution aka the dip. You can see the amount of lead and carbon that came off of the baffles during this process.
    769b970dfc5ccc1f0ab0b53b5488b474.jpg

    In this photo, you can see the baffles soaking in the peracetic acid solution. This solution is known as the dip on the internet. After soaking, the lead and carbon that is built up on the baffle stack is change from a solid state to a liquid state and the peracetic acid solution becomes a highly toxic solution called lead acetate

    f3ecd3e9557187b155d6cc5b69e69ce6.jpg


    The above photo you can see the amount of lead that has been liberated from it's solid state on the baffles and is now floating in the peracetic acid solution

    3cb35fbafc7671fad532a6aa5876a19f.jpg


    493d177788b561ed1d43b4368dc1293e.jpg


    dd8267e98e85727857b6264db8308b94.jpg


    bcf52b2a9f38748a7914b97597ad3500.jpg


    Not all of the lead and carbon is liquefied. As it dissolves, chunks of it fall off of the baffles and are gathered in the bottom of the Mason jar

    58734d998788bc22dbd5d517dcd46976.jpg

    The baffles look far different than they did 16 hours ago when they were placed in the peracetic acid (tyhe Dip) solution. There is lead and carbon residue left on the baffles.

    It is much softer than it was in it's dry and solid-state 16 hours ago.

    After removing the baffles from the peracetic acid solution aka the dip, io rnsed then in fresh water, donned gloves and used a small screwdriver to scrape most of the remaining deposits off of the baffles.

    I did not take pictures of this part of the process. I did video tape it and you will see this step in the video

    693025acf4a1a90254ea06a039ccc29b.jpg


    This left a slushie Solution on the baffle stack witch was removed by the Ultrasonic Cleaner. You will see this step in the video that I made of this process

    c2e8eaf3162c65ae2260afad73fe9b00.jpg




    Sent from my SM-N920V using Tapatalk
     
    Last edited:

    SC-Texas

    TGT Addict
    Lifetime Member
    Emeritus - "Texas Proud"
    Rating - 0%
    0   0   0
    Feb 7, 2009
    6,040
    96
    Houston, TX
    After a 16-hour bath of the dip, a rinsing wash,, a run through the ultrasonic cleaner, and manual scraping, three baffles still had some deposits that would not come off.

    It was time for another few hours in the dip.

    These three baffles were dropped in the peracetic acid solution for another three hours and run through the ultrasonic cleaner again.

    The dead air mask was reassembled and is almost as new

    2bb1b86435e112979e5003ed5f0c876e.jpg

    3 baffles for 3 hours in the dip solution

    b1a8549b69a5f7626ada69e5db7e937a.jpg


    e2a18c4c0a5f3e6710dbb0fc254446d4.jpg


    e67a8416c41120c166c40e95bfb6fdcf.jpg

    These photos of the baffles show the difference that 24 hours, A long soak in the dip and some physical effort make. The mask is as new.

    b4462fd92a6500340692d58bdddac1fb.jpg


    The only downside to using the peracetic acid solution AKA The Dip is the fact that I now have a mason jar full of a highly toxic substance called lead acetate. The disposal requires some special precautions. You cannot just put this in the trash or dump it in the sewer.


    a8199b8e7fa5a3bbcbb932c3bb9432b2.jpg


    c3db0179317af10b578a40dcbcc00d53.jpg


    I wanted to test fit the rear cap of the mask HD on the threads to ensure they were clear after I ran a tap and chased the threads to clean the carbon from the threads.


    After everything was done, the issue of proper disposal of the Paracetic Acid/Lead mix aka Lead acetate solution must be addressed. If you live in Harris County, The Harris County Household Hazardous Waste Facility HCHHWF accepts and disposes of this type of household hazardous waste. It has limited hours for the public.
    Every Wednesday: 9:00 a.m. to 3:00 p.m.
    Every 2nd Saturday of the month: 9:00 a.m. to 2:00 p.m.
    It is located at 6900 Hahl Road (290 and N Gessner) Houston, TX 77040
    Phone: 281.560.6200

    I wanted to test fit the rear cap of the mask HD on the threads to ensure they were clear after I ran a tap to clean the carbon from the threads.


    After everything was done, the issue of proper disposal of the Paracetic Acid/Lead mix aka Lead acetate solution must be addressed. If you live in Harris County, The Harris County Household Hazardous Waste Facility HCHHWF accepts and disposes of this type of household hazardous waste. It has limited hours for the public.
    Every Wednesday: 9:00 a.m. to 3:00 p.m.
    Every 2nd Saturday of the month: 9:00 a.m. to 2:00 p.m.
    It is located at 6900 Hahl Road (290 and N Gessner) Houston, TX 77040
    Phone: 281.560.6200



    Another disposal solution from a chemist.


    "Pour some baking soda in the used solution. It'll bind with lead acetate to form lead sulfate, a precipitate, on the bottom of the tub. Keep pouring until it stops forming, then pour away the remaining solvent. Let the Pb-sulfate dry, then collect in a container. It's still toxic, but not as bad as the luquid acetate form, & safer & easier to deal with."


    Sent from my SM-N920V using Tapatalk
     
    Last edited:

    Fullretard

    Active Member
    Rating - 0%
    0   0   0
    May 11, 2012
    255
    11
    DFW
    Informative post
    Thank you
    I can not bring myself to try the dip, and I will stick to wet tumbling.

    Sent from my SM-G955U using Tapatalk
     

    Davetex

    TGT Addict
    Rating - 100%
    6   0   0
    Mar 27, 2010
    8,456
    96
    Greers Ferry Lake
    I just cleaned my Spectre2 yesterday. It was about that nasty. I soaked all the baffles in mineral spirits for about 24 hours and it really softens all that caked on material pretty well. I still had to use a fair amount of elbow grease though.
     

    deemus

    my mama says I'm special
    Lifetime Member
    Rating - 100%
    30   0   0
    Feb 1, 2010
    15,706
    96
    DFW
    How/where do you dispose of the contents of the mason jar?

    Most large cities have a hazardous waste facility. My town has one. You take your water bill, tell them what you have, and they place it in areas for that type item. Gasoline, paint, acidic solutions, pest control solutions. You name it, they have a spot for it.
     

    SC-Texas

    TGT Addict
    Lifetime Member
    Emeritus - "Texas Proud"
    Rating - 0%
    0   0   0
    Feb 7, 2009
    6,040
    96
    Houston, TX
    How/where do you dispose of the contents of the mason jar?

    If you live in Harris County, The Harris County Household Hazardous Waste Facility HCHHWF accepts and disposes of this type of household hazardous waste. It has limited hours for the public.
    Every Wednesday: 9:00 a.m. to 3:00 p.m.
    Every 2nd Saturday of the month: 9:00 a.m. to 2:00 p.m.
    It is located at 6900 Hahl Road (290 and N Gessner) Houston, TX 77040
    Phone: 281.560.6200
     

    SC-Texas

    TGT Addict
    Lifetime Member
    Emeritus - "Texas Proud"
    Rating - 0%
    0   0   0
    Feb 7, 2009
    6,040
    96
    Houston, TX
    Another disposal solution from a chemist.


    "Pour some baking soda in the used solution. It'll bind with lead acetate to form lead sulfate, a precipitate, on the bottom of the tub. Keep pouring until it stops forming, then pour away the remaining solvent. Let the Pb-sulfate dry, then collect in a container. It's still toxic, but not as bad as the luquid acetate form, & safer & easier to deal with."

    Sent from my SM-N920V using Tapatalk
     

    Txhillbilly

    Active Member
    Rating - 100%
    2   0   0
    Aug 2, 2008
    969
    76
    North Texas
    I clean all of my suppressor's by soaking them in Berryman's Chem-Dip. It comes in a gallon can,and you can get it at Walmart or any Auto parts store.
    It's safe for the entire can to be submerged in it,just soak everything for 24-48 hours,and wipe the carbon/lead off everything with a rag or paper towel. I use it on my Rimfire and Centerfire suppressor's.
     